Back office (OCPP) configuration key list for Alfen NG9 chargers

GetConfiguration & ChangeConfiguration


CategoryComponentKeyname 1.5Keyname 1.6Keyname 2.0.1DescriptionDefault valueMutabilityReboot requiredOrigin
General AlfenStation FeatureObjectId The product unique ID used to purchase a new LicenseKey. Make sure to share this ID on your purchase order. Default: Determined per order
Type: String[25]
Read only No Alfen
General SecurityCtrlr Identity The identity code that is used to identify the charging station (CS) in the back office. Default: Determined per order
Type: String[20]
Read / Write Yes Alfen
General AlfenStation DeviceIdentifier Fixed identifier that is unique per charging station. Default: Determined per order
Type: String[24]
Read only No Alfen
General AlfenStation FeatureLicenseKey Current installed LicenseKey. A new LicenseKey that unlocks features can be purchased from Alfen via a purchase order (webshop or cporders@alfen.com). Default: Determined per order
Type: String[29]
Read / Write No Alfen
General AlfenStation UnlockedFeatures A by comma separated overview of all unlocked features, each feature.
Possibilities:
‐ None
‐ SCN (Smart Charging Network)
‐ Standard‐SC (Static Load balancing)
‐ Active‐SC (Active Load balancing)
‐ 32A‐output
‐ RFID‐reader
‐ Pers.display
- 4G
Default: Determined per order
For instance: None,SCN,Standard-SC,Active-SC,32A-output,RFID-reader,pers.display,4G,Payment-solutions

Type: String[128]
Read only No Alfen
General None SupportedFeatureProfiles Comma separated list of supported featurs.
Options:
- Core
- FirmwareManagement
- LocalAuthListManagement
- Reservation
- SmartCharging
- RemoteTrigger
Default: Determined per order
For instance: Core,FirmwareManagement,Reservation,LocalAuthListManagement,RemoteTrigger,SmartCharging

Type: String[87]
Read only No OCPP
General None SupportedFeatureProfilesMaxLength Maximum number of items in the 'SupportedFeatureProfiles' configuration key. Default: Determined per order
Type: String
Read only No OCPP
General AlfenStation TimeZoneMinutes The time zone offset to UTC in minutes for calculating the local time displayed on the display. Default: 60
Type: Integer (-720 - 720)
Read / Write No Alfen
General AlfenStation Latitude Latitude of the CS location, needed to calculate dusk and dawn for automatically adjusting the LEDs/display intensity after interaction. In sleep mode the display will allways adjust to its lowest intensity. Default: 52.402271
Type: Decimal (-90.0 - 90.0)
Read / Write No Alfen
General AlfenStation Longitude Longitude of the CS location, needed to calculate dusk and dawn for automatically adjusting the LEDs/display intensity after interaction. In sleep mode the display will allways adjust to its lowest intensity. Default: 5.243745
Type: Decimal (-180.0 - 180.0)
Read / Write No Alfen
General AlfenStation Bootloader-Version Information about the bootloader version. Default: Determined per order
Type: String[31]
Read only No Alfen
General AlfenEvse NFC-Version1 NFC-Version Information about the hardware and firmware versions of the NFC reader
HW:,SW:.
Default: Determined per order
Type: String[31]
Read only No Alfen
General AlfenEvse NFC-Version2 NFC-Version Information about the hardware and firmware versions of the NFC reader
HW:,SW:.
Default: Determined per order
Type: String[31]
Read only No Alfen
General AlfenStation OwnerToken This token allows the app and the Alfen cloud to verify that the user is the owner of the charging station. The station itself doesn't need to interact with this value. Default: ''
Type: String[30]
Read only No Alfen
Power settings AlfenStation Station-MaxCurrent MaxCurrent The maximum current (A) that the entire CS is allowed to provide. The Station-MaxCurrent is also used for load balancing at double socket models. Default: Determined per order
Type: Decimal (0.0 - 64.0)
Read / Write No Alfen
Power settings AlfenConnector Connector1-MaxCurrent MaxCurrent Maximum current (A) that an EV is allowed to draw from left connector. Default: Determined per order
Type: Decimal (0.0 - 32.0)
Read / Write No Alfen
Power settings AlfenConnector Connector1.2-MaxCurrent MaxCurrent Maximum current (A) allowed to be drawn from the left E-socket.
Options:
- between 0.0 and 16.0A.
Default: Determined per order
Type: Decimal (0.0 - 32.0)
Read / Write No Alfen
Power settings AlfenConnector Connector1-Type ConnectorType Type of charging socket or cable on connector #1.
Options:
- Fixed cable
- Type 2 socket
- Schuko socket
- Type-1 fixed cable
- Type-2 fixed cable
Default: Determined per order
Type: String[19]
Read / Write Yes Alfen
Power settings AlfenConnector Connector2-MaxCurrent MaxCurrent Maximum current (A) that an EV is allowed to draw from right connector. Default: Determined per order
Type: Decimal (0.0 - 32.0)
Read / Write No Alfen
Power settings AlfenConnector Connector2.2-MaxCurrent MaxCurrent Maximum current (A) allowed to be drawn from the right E-socket.
Options:
- between 0.0 and 16.0A.
Default: Determined per order
Type: Decimal (0.0 - 32.0)
Read / Write No Alfen
Power settings AlfenConnector Connector2-Type ConnectorType Type of charging socket or cable on connector #2.
Options:
- Fixed cable
- Type 2 socket
- Schuko socket
- Type-1 fixed cable
- Type-2 fixed cable
Default: Determined per order
Type: String[19]
Read / Write Yes Alfen
Power settings AlfenStation ZE-ready CS behavior is conform the Renault ZE-ready requirements. Default: False
Type: Boolean
Read / Write Yes Alfen
Power settings AlfenStation Power Outage Recovery Whether the CS will resume the last transaction after a power outage or stays idle. When set to 'Resume' configure the 'Max Allowed Outage Duration (s)' configuration key.
Options:
- Idle
- Resume
Default: Idle
For instance: Resume,Idle

Type: String
Read / Write No Alfen
Power settings AlfenStation Max Allowed Outage Duration (s) When configuration key 'Power Outage Recovery' is set to 'Resume' the charging station will only resume the transaction if the power outage time (s) is less than the set time (s). When this is set to 0, and the 'Power Outage Recovery' is set to 'resume' the transaction will always be resumed. Default: 0
Type: Integer (0 - 3600)
Read / Write No Alfen
Power settings AlfenStation Disable105Percent Enable/Disable the overcurrent check. The CS measures the actual drawn current by the EV. When the maximum allowed current is exceeded by more than 105% the CS will interupt charging. Default: False
Type: Boolean
Read / Write No Alfen
Power settings AlfenStation Chameleon-MinCurrent Minimum required current (A) for charging a Chameleon charger (e.g. Renault Zoe). Upon detecting a Chameleon charger the set value will be used. Default: 14.0
Type: Decimal (6.0 - 32.0)
Read / Write No Alfen
Power settings TxCtrlr ConnectionTimeOut EVConnectionTimeOut Maximum time (s) between presenting an authorized NFC card and connecting an EV before the authorization expires, set to 0 to disable the timeout and wait indefnitelly. Default: 120
Type: Integer (0 - 32767)
Read / Write No OCPP
Power settings AlfenStation AuthorizationTimeOut Maximum time (s) between connecting an EV and authorizing, set to 0 to disable the timeout and wait indefnitelly. Default: 120
Type: Integer (0 - 32767)
Read / Write No Alfen
Power settings AlfenStation Phase-Connected The phase(s) that are connected to the CS and in which order in case active loadbalancing is used. Any combination of L1, L2 and L3. For instance 'L1L2L3', 'L3L2L1' or 'L2' is possible. Default: L1L2L3
Type: String[6]
Read / Write No Alfen
Power settings SmartChargingCtrlr RandomisedDelay Random delay in seconds, this is conferred to the nearest second and a different randomized delay is applied for every change of charging rate as defined in the default charging hours. Default: 0
Type: Integer (0 - 3600)
Read / Write No Alfen
Load balancing AlfenStation Static-LoadBalancing Enable/Disable load balancing between multiple sockets.
Options:
- On
- Off
Configuration key up to FW 3.4.3: 'LoadBalancing'.
Default: Off
For instance: On,Off

Type: String
Read / Write No Alfen
Load balancing AlfenStation Active-LoadBalancing Load balancing in a domestic environment is enabled using a smart meter with P1 port (protocol version DSMR 4.0 and higher)
Configuration key up to FW 3.4.3: 'P1-Port'.
Default: Off
For instance: On,Off

Type: String
Read / Write No Alfen
Load balancing AlfenStation ALB-ProtocolSelection Select what device will be used as a smartMeter for the active loadbalancing. Default: None
For instance: None,Modbus TCP/IP,External modbus,TIC,DSMR P1

Type: String
Read / Write No Alfen
Load balancing AlfenStation RJ11-Mode Configure for which purpose you want to use the RJ11 port.
Options:
- DSMR P1
- Suspend when an external circuit is closed
- Suspend when an external circuit is opened.
Default: DSMR P1
For instance: DSMR P1,closed,open

Type: String
Read / Write Yes Alfen
Load balancing AlfenStation MBTCPSmart-IPAddress IP address of the Modbus TCP/IP meter. Determined and set during installation.
Configuration key up to FW 3.4.3: 'MBTCP-IPAddress'.
Default: 192.168.000.005
Type: String
Read / Write No Alfen
Load balancing AlfenStation MBTCPSmart-Port Port of the Modbus TCP/IP smart meter. Default: 502
Type: Integer (0 - 65535)
Read / Write No Alfen
Load balancing AlfenStation MBTCPSmart-IsEnabled Enable/Disable Modbus TCP/IP.
Configuration key up to FW 3.4.3: 'MBTCP-IsEnabled'.
Default: False
Type: Boolean
Read / Write Yes Alfen
Load balancing AlfenStation MBTCPSmart-SlaveUnitID Slave address of the Smart Modbus TCP/IP meter.
Options:
- From 0 to 65535.
Default: 5
Type: Integer (0 - 65535)
Read / Write No Alfen
Load balancing AlfenStation MBTCPSmart-SlaveMeterModel The band / type of Modbus TCP/IP meter that is used for active loadbalancing.
Options:
- None
- Socomec
- Regmap (custom register mapping)
Default: Socomec
For instance: None,socomec,regmap

Type: String
Read / Write No Alfen
Load balancing AlfenStation MbsSlaveTCPIP Enable or disable the modbus slave functionality. Default: Off
For instance: On,Off

Type: String
Read / Write No Alfen
Load balancing AlfenStation MbsSlaveTCPIPValidityTime Time in seconds in which the charging station requires an updated maximum current from a Modbus master before falling back to the safe current. Default: 60
Type: Integer (1 - 32767)
Read / Write No Alfen
Load balancing AlfenStation MbsSlaveTCPIPMode Control each socket or control the charging station as a complete station. Default: Off
For instance: Off,Socket,SCN

Type: String
Read / Write No Alfen
Load balancing AlfenStation Safe-MaxCurrent The safe current (A) that the CS will use when active loadbalancing loses connection. (For instance: CS loses connection to the smart meter or to the SCN). Default: 16.0
Type: Decimal
Read / Write No Alfen
Load balancing AlfenStation SCN-AlternatingPeriod When the sum of all minimum charging currents is higher than the available current for the Smart Charging Network, the Smart Charging Network will alternate the sockets between charging and suspending.

During AlternatingPeriod:
Charging time per socket = 'SCN-AlternatingPeriod' (s) / number of active charging sessions in the Smart Charging Network.
Default: 900
Type: Integer (900 - 36000)
Read / Write No Alfen
Load balancing AlfenStation SCN-IsEnabled Is Smart Charging Network unlocked. Default: Determined per order
Type: Boolean
Read only No Alfen
Load balancing AlfenStation SCN-NetworkName Name of the Smart Charging Network. This should be identical for all CSs in one Smart Charging Network. Default: SCN1
Type: String[7]
Read / Write No Alfen
Load balancing AlfenEvse SCN-PhaseMapping-1 SCN-PhaseMapping Configure based on the order that the phases are connected inside the CS. Phase mapping is used by the Smart Charging Network to adjust available current per socket. For single feeder cable models 'SCN-PhaseMapping-1' (left socket) is identical to 'SCN-PhaseMapping-2' (right socket).
Options:
- 0 = None
- 1 = L1
- 2 = L2
- 3 = L3
- 4 = L1L2L3
- 5 = L1L3L2
- 6 = L2L1L3
- 7 = L2L3L1
- 8 = L3L1L2
- 9 = L3L2L1
It's advised to apply phase mapping in the following order:
L1 L2 L3 -> L3 L1 L2 -> L2 L3 L1 -> and continue in this order.
Default: 4
Type: Integer (0 - 9)
Read / Write No Alfen
Load balancing AlfenEvse SCN-PhaseMapping-2 SCN-PhaseMapping Configure based on the order that the phases are connected inside the CS. Phase mapping is used by the Smart Charging Network to adjust available current per socket. For single feeder cable models 'SCN-PhaseMapping-1' (left socket) is identical to 'SCN-PhaseMapping-2' (right socket).
Options:
- 0 = None
- 1 = L1
- 2 = L2
- 3 = L3
- 4 = L1L2L3
- 5 = L1L3L2
- 6 = L2L1L3
- 7 = L2L3L1
- 8 = L3L1L2
- 9 = L3L2L1
It's advised to apply phase mapping in the following order:
L1 L2 L3 -> L3 L1 L2 -> L2 L3 L1 -> and continue in this order.
Default: 4
Type: Integer (0 - 9)
Read / Write No Alfen
Load balancing AlfenStation SCN-SocketSafeCurrent The maximum current (A) that the socket will use when the Smart Charging Network lost the connection with CS. This value should always be identical for all of the CSs in one Smart Charging Network. Default: 6.0
Type: Decimal
Read / Write No Alfen
Load balancing AlfenStation SCN-TotalSafeCurrent The maximum current (A) that a SCN will use when multiple sockets lost the connection. The number of sockets charging on SCN-SocketSafeCurrent will be limited so the total will not surpass SCN-TotalSafeCurrent. Default: 32.0
Type: Decimal
Read / Write No Alfen
Load balancing AlfenStation SCN-SocketCount Total number of sockets in the Smart Charging Network. Eve single has 1 socket, Eve double has 2 sockets, etc... Determined by initialization during installation. Default: Determined per order
Type: Integer (0 - 255)
Read / Write No Alfen
Load balancing AlfenStation SCN-SocketID The ID of the left socket that is defined by the Smart Charging Network. This should always be unique and in chronologic order for all sockets in the Smart Charging Network. Determined by initialization during installation. Default: 0
Type: Integer (0 - 255)
Read / Write No Alfen
Load balancing AlfenStation SCN-TotalStaticCurrent The maximum current (A) that the Smart Charging Network will use. This value should always be identical for all of the CSs in one Smart Charging Network. Default: 200.0
Type: Decimal
Read / Write No Alfen
Load balancing SmartChargingCtrlr ChargeProfileMaxStackLevel ProfileStackLevel Max StackLevel of a ChargingProfile. The number defined also indicates the max allowed number of installed ChargingProfiles per Charging Profile Purpose. Default: 5
Type: Integer
Read only No OCPP
Load balancing None ChargingScheduleAllowedChargingRateUnit A list of supported quantities for use in a ChargingSchedule. Default: Current
For instance: Current

Type: String
Read only No OCPP
Load balancing SmartChargingCtrlr ChargingScheduleMaxPeriods PeriodsPerSchedule Maximum number of periods that may be defined per ChargingSchedule. Default: 10
Type: Integer
Read only No OCPP
Load balancing None MaxChargingProfilesInstalled Maximum number of charging profiles installed. Default: 20
Type: String
Read only No OCPP
Load balancing AlfenStation NuvveActive Switch the Nuvve functionality on or off. Default: False
Type: Boolean
Write only No Alfen
Load balancing AlfenStation NuvveInterval Interval (s) in which the Nuvve message is being send. Default: 60
Type: Integer (0 - 65535)
Write only No Alfen
Load balancing AlfenStation NuvveTolerance Minimum power change to active the sending of the Nuvve message in W.

Check whether this can be deleted (via Wouter/NM).
Default: 100
Type: Integer (0 - 65535)
Write only No Alfen
Load balancing SmartChargingCtrlr ConnectorSwitch3to1PhaseSupported Phases3to1 If True, the CS supports switching from 3 to 1 phase during a charging session. Default: False
Type: Boolean
Read only No OCPP
Load balancing AlfenStation SmartChargingMode OCPP 1.5+ smart charging mode. This smart charging mode only functions when the OCPP protocol version is set to 1.5.
Options:
- None
- GreenFlux
- Enervalis
- Cohere
- EVNet
- OCPP16
Default: None
For instance: None,GreenFlux,Enervalis,Cohere,EVNet,OCPP16

Type: String
Read / Write No Alfen
Load balancing None ConnectorPhaseRotation The phase rotation per connector in respect to the connectors energy meter (or if absent, the grid connection).
Options:
- NotApplicable (for Single phase or DC CSs)
- Unknown (not (yet) known)
- RST (Standard Reference Phasing)
- RTS (Reversed Reference Phasing)
- SRT (Reversed 240 degree rotation)
- STR (Standard 120 degree rotation)
- TRS (Standard 240 degree rotation)
- TSR (Reversed 120 degree rotation)
R can be identified as phase 1 (L1), S as phase 2 (L2), T as phase 3 (L3). If known, the CS MAY also report the phase rotation between the
grid connection and the main energymeter by using index number Zero (0).
Values are reported in CSL, formatted:
0.RST, 1.RST, 2.RTS
Default: 0.RST
For instance: 0.Unknown,0.NotApplicable,0.RST,0.RTS,0.SRT,0.STR,0.TRS,0.TSR

Type: String
Read / Write No OCPP
Load balancing None ConnectorPhaseRotationMaxLength Maximum number of items in a ConnectorPhaseRotation Configuration Key. Default: 0
Type: String
Read only No OCPP
Load balancing AlfenStation SmartMeter-MaxCurrent The maximum current (A) of the entire electrical installation. This value is required for installations with a smart meter to determine the available power that the EV may consume.
Configuration key up to FW 3.4.3: 'Installation-MaxCurrent'.
Default: 25.0
Type: Decimal
Read / Write No Alfen
Load balancing AlfenStation SmartMeterIncludesCharger Indicates whether the readings from the external meter include the stations consumption.
Options:
- True
- False
Default: True
Type: Boolean
Read / Write No Alfen
Load balancing AlfenStation MBTCPCentral-IPAddress IP address of the Modbus TCP/IP meter. Default: 192.168.000.004
Type: String
Read / Write No Alfen
Load balancing AlfenStation MBTCPCentral-Port Port of the Modbus TCP/IP central meter. Default: 502
Type: Integer (0 - 65535)
Read / Write No Alfen
Load balancing AlfenStation MBTCPCentral-IsEnabled Enable/Disable Modbus TCP/IP.
Options:
- True
- False
Default: False
Type: Boolean
Read / Write Yes Alfen
Load balancing AlfenStation MBTCPCentral-SlaveUnitID Slave address of the Central Modbus TCP/IP meter.
Options:
- From 0 to 65535
Default: 5
Type: Integer (0 - 65535)
Read / Write No Alfen
Load balancing AlfenStation MBTCPCentral-SlaveMeterModel The band / type of Modbus TCP/IP meter that is used for active loadbalancing.
Options:
- None
- Socomec
- Regmap (custom register mapping)
Default: Socomec
For instance: None,socomec,regmap

Type: String
Read / Write No Alfen
Load balancing AlfenStation EnablePhaseSwitching Enable switching between 1 and 3 phase charging. Default: False
Type: Boolean
Read / Write No Alfen
Load balancing AlfenStation MaxImbalanceCurrent The maximum allowed imbalance between phases. Default: 0.0
Type: Decimal (0.0 - 99.0)
Read / Write No Alfen
Load balancing AlfenStation MaxAllowedPhases Maximum number of phases that the CP is allowed to charge on. Default: 3
Type: Integer (1 - 3)
Read / Write No Alfen
Load balancing AlfenStation SC-Mode SolarCharging optimizes locally generated, excess power as measured by the smart meter. Must have Active Loadbalancing configured.
- Green: SC-GreenShare is configurable
- Comfort: SC-ComfortLevel is configurable
Default: Off
For instance: Off,Comfort,Green

Type: String
Read / Write No Alfen
Load balancing AlfenStation SC-GreenShare Only used if 'SC-Mode' is configured as 'Green', value in percentages.
- If set to 0%, charging at minimum power is always possible.
- If set to 100%, charging will only take place if minimum power to charge is measured as excess power on smart meter
Charging speed will increase to match excess power as measured on smart meter.
Default: 0
Type: Integer (0 - 100)
Read / Write No Alfen
Load balancing AlfenStation SC-ComfortLevel Only used if 'SC-Mode' is configured as 'Comfort'. Charging will always start irrespective of amount of excess power as measured on smart meter. Value, in W, is configured as desired minimum charging power.
Charging speed will increase above Comfort Level to match excess power as measured on smart meter, never exceeding configured maximum current. If Comfort Level exceeds maximum available current, charging will not exceed maximum.
Default: 1400
Type: Integer (1400 - 22000)
Read / Write No Alfen
Authorization AlfenStation DisconnectAction The behavior of the CS when an EV is disconnected during a transaction.
Options:
- Continue: When the cable is removed on the EV side, the plug will stay locked on the CS side and the transaction will not be stopped by the CS. As soon as you plug the cable back into the EV, the charging continues and all transaction data will be registered to the transaction that is still running.
- Abort lock: When the cable is removed on the EV side, the plug will stay locked on CS side and the CS will wait for deauthorization, by the same tag that started the transaction, before stopping the transaction and unlocking the cable.
- Abort unlock: When the cable is removed on the EV side, the transaction will be stopped by the CS and the cable will be unlocked.
- Abort unlock when offline: When the cable is removed on the EV side and the CS is offline or goes offline while waiting for deauthorization, by the same tag that started the transaction, then the scenario for "abort unlock" will be followed. Otherwise the scenario for "abort lock" will be followed.

If the CS has a fixed cable or is authorised via P&C or direct payment, then scenario "abort unlock" will be followed.
Default: Continue
For instance: Continue,Abort,Unlock,UnlockWhenOffline

Type: String
Read / Write No Alfen
Authorization OCPPCommCtrlr UnlockConnectorOnEVSideDisconnect UnlockOnEVSideDisconnect When set to true, the CS shall unlock the cable on CS side when the cable is unplugged at the EV.
This depends on the value that is set for configuration key 'DisconnectAction'.
Default: False
Type: Boolean
Read / Write No OCPP
Authorization AlfenStation DisconnectTimeout Time (s) after which configuration key 'DisconnectAction' is executed by the CS. Default: 10
Type: Integer (0 - 32767)
Read / Write No Alfen
Authorization AlfenStation AbortConcurrentTx Abort an ongoing transaction when a back office reports a 'ConcurrentTx' status as a reply to the StartTransaction request. Default: False
Type: Boolean
Read / Write No Alfen
Authorization AuthCtrlr AllowOfflineTxForUnknownId OfflineTxForUnknownIdEnabled Allow transactions for unknown identifiers when CS is offline.

When the CS is online again the status of the identifier is checked and updated in the whitelist accordingly.
Default: True
Type: Boolean
Read / Write No OCPP
Authorization AuthCacheCtrlr AuthorizationCacheEnabled Enabled Indicates whether the CS has an Authorization Cache or not.
Options:
True: Authorization Cache present.
False: Authorization Cache not present.
Default: True
Type: Boolean
Read / Write No OCPP
Authorization AlfenStation AuthorizationMethod The interaction used by the CS to start a transaction.
Options:
- RFID: CS always requires an RFID card to start charging.
- Plug&Charge: CS will always use the configured configuration key 'PlugAndChargeIdentifier' to start a transaction upon detecting an Electric Vehicle (EV).
Default: Determined per order
For instance: plug&charge,rfid,button

Type: String
Read / Write No Alfen
Authorization AuthCtrlr AuthorizeRemoteTxRequests AuthorizeRemoteStart Verify whether the used identifier used in a RemoteStartTransaction request is authorised by the back office before starting the transaction. Default: False
Type: Boolean
Read / Write No OCPP
Authorization LocalAuthListCtrlr LocalAuthListEnabled Enabled Enable/Disable the local authorization list. Default: True
Type: Boolean
Read / Write No OCPP
Authorization None LocalAuthListMaxLength Maximum number of identifications that can be stored in the Local Authorization List. Default: 782
Type: String
Read only No OCPP
Authorization AuthCtrlr LocalAuthorizeOffline Whether an offline CS will start a transaction for locally authorized identifiers. Default: True
Type: Boolean
Read / Write No OCPP
Authorization AuthCtrlr LocalPreAuthorize Whether an online CS will start a transaction for locally authorized identifiers. The identifier will be verified based on the StartTransaction.req by the back office. Default: False
Type: String
Read / Write No OCPP
Authorization AlfenStation PlugAndChargeIdentifier Identification that a Plug&Charge CS will use to report transactions to the back office. Default: ''
Type: String[20]
Read / Write No Alfen
Authorization AlfenStation OfflineAuthorise Authorize an unknown identification that is presented while the CS is offline.

Made write only because this became absolete and is now replaced by OCPP config key 'LocalAuthorizeOffline'.
Default: True
Type: Boolean
Write only No Alfen
Authorization AlfenStation OnlineAuthorise Always authorize an NFC card at the back office when online, even if the tag is known in the white list or the local list.

Made write only because this became absolete and is now replaced by OCPP config key 'LocalPreAuthorize'.
Default: True
Type: Boolean
Write only No Alfen
Authorization AlfenStation WhiteListEnabled Enable/Disable the Authorization Cache. If this key does not exist the Authorization Cache is disabled. Default: True
Type: Boolean
Read / Write No Alfen
Authorization TxCtrlr MaxEnergyOnInvalidId Maximum amount of energy in Wh delivered when an identifier is deauthorized by the CSMS after start of a transaction. Default: 0
Type: Integer (0 - 4294967295U)
Read / Write No OCPP
Authorization None SendLocalListMaxLength Maximum number of identifications that can be sent in a single SendLocalList.req Default: 22
Type: String
Read only No OCPP
Authorization TxCtrlr StopTransactionOnEVSideDisconnect StopTxOnEVSideDisconnect When set to true, the CS shall stop the transaction when the cable is unplugged from the EV.
This depends on the value that is set for configuration key 'DisconnectAction'.
Default: False
Type: Boolean
Read / Write No OCPP
Authorization AlfenStation TimeUnlockWhenNotCharging Time (s) after an EV stops charging until the CS will stop the transaction and unlock the cable. Default: 0
Type: Integer (0 - 32767)
Read / Write No Alfen
Authorization TxCtrlr StopTransactionOnInvalidId StopTxOnInvalidId The minimum duration that a Charge Point or Connector status is stable
before a StatusNotification.req PDU is sent to the Central System.
Default: False
Type: Boolean
Read / Write No OCPP
Authorization AlfenStation MasterKey-isEnabled When master key is enabled, the CS can enter the special master key mode when the master key is detected, enabling the user to add and/or remove tags from the internal tag database.
Options:
- True (default for stand-alone charging stations)
- False (default for charging stations connected to a back office)
Default: Determined per order
Type: Boolean
Read / Write No Alfen
Authorization AlfenStation MasterKey-Id The ID of the tag that is defined as master key. Default: ''
Type: String[21]
Read / Write No Alfen
Authorization AuthCtrlr MasterPassGroupId IdTokens that have this id as groupId belong to the Master Pass Group. Meaning they can stop any ongoing transaction, but cannot start transactions. This can, for example, be used by law enforcement personal to stop any ongoing transaction when an EV has to be towed away. Default: ''
Type: String[36]
Read / Write No OCPP
Connectivity OCPPCommCtrlr TransactionMessageAttempts MessageAttempts Maximum number of times that the CS retries to submit a transaction-related message when the back offfice fails to process it. Default: 0
Type: Integer (0 - 65535)
Read / Write No OCPP
Connectivity OCPPCommCtrlr TransactionMessageRetryInterval MessageAttemptInterval Wait time (s) between resubmitting transaction related messages that the back office failed to process. Default: 60
Type: Integer (0 - 2147483647)
Read / Write No OCPP
Connectivity OCPPCommCtrlr WebSocketPingInterval Interval (s) between pings (only relevant for Websocket connections). Set to '0' to disable client side websocket Ping/Pong. In this case there is either no ping/pong or the server initiates the ping and client (CS) responds with Pong. Default: 120
Type: Integer (0 - 2147483647)
Read / Write No OCPP
Connectivity AlfenStation APN-SignalStrength Strength of the mobile signal (dBm). Default: ''
Type: Integer
Read only No Alfen
Connectivity None AuthorizationKey Authorization key used by the CS to set up the websocket communication. Default: ''
Type: String[40]
Read / Write No Alfen
Connectivity AlfenStation DNS-1 Preferred GPRS DNS address. Default: 8.8.8.8
Type: String
Read / Write No Alfen
Connectivity AlfenStation DNS-2 Fallback GPRS DNS address for when the preferred DNS address results in a dead end. Default: 208.67.222.222
Type: String
Read / Write No Alfen
Connectivity AlfenStation CentralMeterValueAlignment Time alignment for sending the central meter values messages.
Options:
- clock: Send meter values every x-seconds aligned with clock-hours.
- boot: Send meter values every x-seconds aligned with time of booting.
Default: clock
For instance: clock,boot

Type: String
Read / Write No Alfen
Connectivity AlfenStation CentralMeterValueSampleInterval Time (s) between central meter values messages of the central energy meter.
Set to '0' to disable sending of the central meter values.
Default: 900
Type: Integer (0 - 65535)
Read / Write No Alfen
Connectivity AlfenStation CentralMeterValueTransmissionMode Determine when meter values from the central energy meter should be send to the back office. Interval is based on 'CentralMeterValueSampleInterval'.
Options:
- During: Send only during transactions
- Always: Always send meter values (based on 'CentralMeterValueAlignment')
- End: Only send at the end of a transaction
Default: during
For instance: during,end,always

Type: String
Read / Write No Alfen
Connectivity OCPPCommCtrlr heartbeatInterval HeartbeatInterval Maximum elapsed time (s) from the last successful back office message exchange until a new heartbeat message will be sent.
Set to '0' to disable sending of heart beats.
Default: 900
Type: Integer (30 - 2147483647)
Read / Write No OCPP
Connectivity AlfenStation HeartBeatSendAllways Configure the CS to send a HeartBeat even if other messages are send and replied to by the back office. Default: False
Type: Boolean
Read / Write No Alfen
Connectivity AlfenStation MaxTxMeterValueRandomisationTime To prevent server overload when multiple CSs simultaneously send meter values. Meter value messages will be send at a randomized interval between 0 and the programmed amount of seconds.
Set to 0 to switch off the randomization.
Default: 0
Type: Integer (0 - 65535)
Read / Write No Alfen
Connectivity AlignedDataCtrlr ClockAlignedDataInterval Interval Interval time (s) that the CS sends clock-aligned data. Clock aligned data is send based on clock time. When value = 900 data will be send at 00:15, 00:30, 00:45, 01:00, 01:15, etc..
'0' to disable clock data (default is 0 because per default 'MeterValueSampleInterval' is being used).
Default: 0
Type: Integer (0 - 999999)
Read / Write No OCPP
Connectivity AlignedDataCtrlr MeterValuesAlignedData Measurands Clock-aligned measurand(s) to be included in every meter value. The interval can be changed by changing the key 'ClockAlignedDataInterval'. A combination, up to 9, of measurands is supported

The measurand(s) that are supported are the same as for configuration key 'MeterValuesSampledData'.
Default: None
For instance: Current.Import,Energy.Active.Import.Register,Energy.Reactive.Import.Register,Energy.Active.Import.Interval,Energy.Active.Net,Energy.Reactive.Import.Interval,Energy.Reactive.Net,Energy.Apparent.Import,Frequency,Power.Active.Import,Power.Factor,Power.Reactive.Import

Type: Memberlist
Read / Write No OCPP
Connectivity None MeterValuesAlignedDataMaxLength Maximum number of items in the configuration key 'MeterValuesAlignedData'. Default: 9
Type: String
Read only No OCPP
Connectivity SampledDataCtrlr MeterValueSampleInterval TxUpdatedInterval Interval time (s) that the CS sends sampled data. Sampled data is send related to the start time of the transaction. For instance, a value of 900 indicates that every 15 minutes data will be send during a transaction.

'0' to disable sampled meter values.
Default: 900
Type: Integer (0 - 2147483647)
Read / Write No OCPP
Connectivity SampledDataCtrlr MeterValuesSampledData TxUpdatedMeasurands Sampled measurand(s) to be included in every meter value. The interval can be changed by changing the key 'MeterValueSampleInterval'. A combination, up to 9, of measurands is supported. The measurands can be combined by separating the value by a comma ','
Value example: 'Energy.Active.Import.Register,Voltage.L1-N,Current.Import.L1'

Supported values:
Energy.Active.Import.Register, Power.Active.Import, Current.Import, Voltage, Temperature, Current.Offered, Frequency, Power.Factor

Measurand(s) must be combined with the phase (separated by a dot '.')
Supported phases:
Voltage meter values support phase configuration:
L1-N, L2-N, L3-N, L1-L2, L2-L3, L3-L1
Value example: 'Voltage.L1-N'

Current, power and power factor meter values support phase configuration:
L1, L2, L3
Value example: 'Current.Import.L1'

When the 'SmartChargingMode' (OCPP 1.5+) is beeing used, the following measurands are available:
Supported values:
Current.L1, Current.L2, Current.L3
Default: Energy.Active.Import.Register
For instance: Current.Import,Energy.Active.Import.Register,Energy.Reactive.Import.Register,Energy.Active.Import.Interval,Energy.Active.Net,Energy.Reactive.Import.Interval,Energy.Reactive.Net,Energy.Apparent.Import,Frequency,Power.Active.Import,Power.Factor,Power.Reactive.Import

Type: Memberlist
Read / Write No OCPP
Connectivity None MeterValuesSampledDataMaxLength Maximum number of items in the configuration key 'MeterValuesSampledData'. Default: 9
Type: String
Read only No OCPP
Connectivity AlfenStation OCPP-reply timeout Time (s) after which a CS determines that setting up a websocket connection via GPRS failed. Default: 5
Type: Integer (5 - 65535)
Write only No Alfen
Connectivity AlfenStation OCPP-send timeout Time (s) after which an OCPP request send by CS is timed out. Default: 100
Type: Integer (60 - 65535)
Write only No Alfen
Connectivity AlignedDataCtrlr StopTxnAlignedData TxEndedMeasurands Whether the CS will include a clock aligned metervalue in the StopTransaction.req.
Only Energy.Active.Import.Register is supported.
Default: ''
For instance: Energy.Active.Import.Register

Type: Memberlist
Read / Write No OCPP
Connectivity None StopTxnAlignedDataMaxLength Maximum number of items in a StopTxnAlignedData Configuration Key.
This is currently not supported and will always return 0.
Default: 0
Type: String
Read only No OCPP
Connectivity SampledDataCtrlr StopTxnSampledData TxEndedMeasurands Whether the CS will include a sampled metervalue relative to the start of the transactoin in the StopTransaction.req.
Only Energy.Active.Import.Register is supported.
Default: ''
For instance: Energy.Active.Import.Register

Type: Memberlist
Read / Write No OCPP
Connectivity None StopTxnSampledDataMaxLength Maximum number of items in a StopTxnSampledData Configuration Key.
This is currently not supported and will always return 0.
Default: 0
Type: String
Read only No OCPP
Connectivity AlfenStation ProxyEnable Enable proxy service, allowing the charging station to log in to a proxy server within the local network.
Options:
- True
- False
Default: False
Type: Boolean
Read / Write No Alfen
Connectivity AlfenStation ProxyAddressAndPort Local Proxy server IP address and port. Default: ''
Type: String[64]
Read / Write No Alfen
Connectivity AlfenStation ProxyUsername Username to log in to local Proxy server. Default: ''
Type: String[32]
Read / Write No Alfen
Connectivity AlfenStation ProxyPassword Password to log in to local Proxy server. Default: ''
Type: String[40]
Write only No Alfen
Connectivity OCPPCommCtrlr SupportedFileTransferProtocols FileTransferProtocols The supported transfer protocols that can be used for getDiagnostics or updateFirmware. Default: FTP
For instance: FTP

Type: Memberlist
Read only No OCPP
Connectivity AlfenStation OCPPStackVersion Indicate the OCPP stack version. This item is 'somewhat' required for the OCPP certification i.e.: we don't need to certify new firmware when the OCPP stack version is not touched. This version number should be updated whenever a change is done to either the OCPP message handling or to any behaviour that influences OCPP messaging. For now, this version number is maintained manually. Default: 4.7.0
Type: String
Read only No OCPP
Connectivity AlfenStation MobileNetworkPreference This key sets the preferred Radio Access Technology when the charging station is booted. The actual Radio Access Technology may change depending on modem capabilities and the setting of the 'MobileNetworkSelection' key. Writing a new value will be rejected if the installed modem does not support the requested Radio Access Technology. Default: Determined per order
For instance: 2G,3G,4G

Type: String
Read / Write Yes Alfen
Connectivity AlfenStation MobileNetworkSelection When set to 'manual', the modem is forced to use the Radio Access Technology as specified in key 'MobileNetworkPreference'. When set to 'auto', the Charging Station may decide to use another supported Radio Access Technology to establish communication to the Central System. Default: auto
For instance: auto,manual

Type: String
Read / Write Yes Alfen
Connectivity AlfenStation ModemManufacturer Manufacturer of the modem. Default: ''
Type: String[64]
Read only No Alfen
Connectivity AlfenStation ModemModel Model of the modem. Default: ''
Type: String[64]
Read only No Alfen
Connectivity AlfenStation ModemRevision Software revision of the modem firmware. Default: ''
Type: String[64]
Read only No Alfen
Connectivity SampledDataCtrlr RegisterMeterValuesIncludePhases Include individual phase measurands in the metervalue message. Default: False
Type: Boolean
Read / Write No OCPP
Connectivity AlfenStation BackOfficeNetworkProfile1 The format of the configkey is VARIABLENAME{VALUE}.
While the CSMS and APN values can be up to 512 characters in OCPP 201, these will be truncated to 200 characters in OCPP 1.5/1.6.
Allowed characters: allowed characters in URL: ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz0123456789-._~:/?#[]@!$&'()*+,;=
The OCPP 2.0.1 fields preferredNetwork and apnAuthentication are not implemented, thus not part of the message.
For the ethernet interface use WIRED0, for the mobile network use WIRELESS0 and for the wifi interface use WIRELESS1.
APN variables are only applicable when using WIRELESS0
Examples:
ocppVersion{OCPP16}ocppCsmsUrl{ws.....}messageTimeout{10}securityProfile{1}ocppInterface{Wired1}
ocppVersion{OCPP16}ocppCsmsUrl{ws://169.254.19.56:7364}messageTimeout{15}securityProfile{0}ocppInterface{Wired0}apn{machine.m2m}APN-User{}preferredNetwork{}apnAuthentication{AUTO}
ocppVersion{OCPP15}ocppCsmsUrl{ws:/}messageTimeout{15}securityProfile{0}ocppInterface{Wired0}apn{alfen.m2m}APN-User{}preferredNetwork{}apnAuthentication{}
ocppVersion{OCPP16}ocppCsmsUrl{ws://169.254.19.56:7364}messageTimeout{15}securityProfile{0}ocppInterface{Wired0}preferredNetwork{}apnAuthentication{AUTO}
ocppVersion{OCP201}ocppCsmsUrl{ws:/}messageTimeout{15}securityProfile{0}ocppInterface{Wired0}preferredNetwork{}apnAuthentication{}
ocppVersion{}ocppCsmsUrl{}messageTimeout{0}securityProfile{0}ocppInterface{}preferredNetwork{}apnAuthentication{}

The priorities can be get and set via the priorities configuration key, this is a list, just as described in the OCPP 2.0.1 specification. Changing these priorites will only be effectuated after a reboot.
Default: ''
Type: String[500]
Read / Write No Alfen
Connectivity AlfenStation BackOfficeNetworkProfile2 See BackOfficeNetworkProfile1. Default: ''
Type: String[500]
Read / Write No Alfen
Connectivity AlfenStation BackOfficeNetworkProfile3 See BackOfficeNetworkProfile1. Default: ''
Type: String[500]
Read / Write No Alfen
Connectivity AlfenStation BackOfficeNetworkProfile4 See BackOfficeNetworkProfile1. Default: ''
Type: String[500]
Read / Write No Alfen
Connectivity OCPPCommCtrlr NetworkConfigurationPriority A comma separated ordered list of the priority of the possible Network Connection Profiles. Default: ''
For instance: 1,2,3,4

Type: Sequencelist
Read / Write Yes Alfen
Connectivity OCPPCommCtrlr NetworkProfileConnectionAttempts Specifies the number of connection attempts the Charging Station executes before switching to a different profile. Default: 3
Type: Integer (0 - 127)
Read / Write No Alfen
Connectivity OCPPCommCtrlr MinimumStatusDuration The minimum duration that a Charge Point or Connector status is stable
before a StatusNotification.req PDU is sent to the Central System.
Default: 0
Type: Integer (0 - 65535)
Read / Write No OCPP
Interface AlfenStation StatusNotificationMode The transmissioning mode for StatusNotification messages.
Options:
- Normal, Time of message received on back office side is seen as time of message sent from CS side. When CS is offline it doesn't queue status notifications.
- Timestamp, A time stamp is added to the status notification from CS side. When CS is offline it doesn't queue status notifications.
- Queued, A time stamp is added to the status notification from CS side. When CS is offline the status notifications are being queued and send when CS is back online.
Default: Normal
For instance: Normal,Timestamp,Queued

Type: String
Read / Write No Alfen
Interface AlfenStation InformationalStatusNotifications Whether or not informational StatusNotifications should be transmitted. Default: Enabled
For instance: Disabled,Enabled

Type: String
Write only No Alfen
Interface AlfenStation AutoDimLights If the screen needs to dim based on time (thus will dimm during the night, this requires an accurate time synchronization such as an heartbeat), inactivity (when a user interacts with the charging station, the display will light up again), if a qr is shown or a combination of these options Default: time,inactivity
For instance: time,inactivity,qr

Type: Memberlist
Read / Write No Alfen
Interface None LightIntensity Light intensity (%) of the LEDs/display. Default: 100
Type: Integer (0 - 100)
Read / Write No OCPP
Interface AlfenStation CalibrateTilt Calibrate and enable the tilt sensor. Default: ''
Type: String
Write only No Alfen
Interface AlfenStation Language Display language is a combination of ISO language code (ISO-639-1) and ISO country code (ISO-3166) in format [language_COUNTRY]
Options:
- English = en_GB
- Dutch = nl_NL
- German = de_DE
- French = fr_FR
- Italian = it_IT
- Norwegian = nn_NO
- Finnish = fi_FI
- Portuguese = pt_PT
- Spanish = es_ES
- Swedish = sv_SE
- Polish = pl_PL
- Danish = da_DK
- Czech = cs_CZ
- Hungarian = hu_HU
- Latvian = lv_LV
- Slovenian = sl_SI
- Romanian = ro_RO
- Slovak = sk_SK
- Icelandic = is_IS
- Catalan = ca_ES
- Croatian = hr_HR
Default: Determined per order
For instance: en_GB,nl_NL,de_DE,fr_FR,it_IT,nn_NO,fi_FI,pt_PT,es_ES,sv_SE,pl_PL,da_DK,cs_CZ,hu_HU,lv_LV,sl_SI,ro_RO,sk_SK,is_IS,ca_ES,hr_HR

Type: String
Read / Write No Alfen
Interface AlfenStation LED Heart Beat Intensity Maximum light intensity (%) of the NFC status notification LED. Default: 100
Type: Integer (0 - 100)
Read / Write No Alfen
Interface AlfenStation LED Heart Beat Mode Enable/Disable the NFC status notification LED. Default: Off
For instance: Off,Glow

Type: String
Read / Write No Alfen
Interface AlfenStation Cover lock enabled Enable/Disable the socket cover locking mechanism. Default: True
Type: Boolean
Read / Write Yes Alfen
Interface AlfenStation NFCLEDMode (0) Disable, (1) Enable the NFC status notification LED, and (2) UI LED Enable. Default: 1
Type: Integer (0 - 2)
Read / Write Yes Alfen
Alerts AlfenStation TimeReportWhenNotCharging Time (s) after an EV stops charging until the CS will report a warning and display orange leds status. Default: 0
Type: Integer (0 - 65535)
Write only No Alfen
Alerts AlfenStation TemperatureHigh The set upper internal temperature limit (°C) on which a CS will send a temperature alert and pauses charging. Default: 70.0
Type: Decimal
Read / Write No Alfen
Alerts AlfenStation TemperatureLow The set lower internal temperature limit (°C) on which a CS will send a temperature alert and pauses charging. Default: -25.0
Type: Decimal
Read / Write No Alfen
Alerts AlfenStation ContactorProtect The time (s) during which the CS accepts a maximum of 10 start/stop charging requests from the EV. If more switches are counted in this period, the station will go into error state. Default: 60
Type: Integer (0 - 32767)
Read / Write No Alfen
Alerts AlfenStation 6mADetectResponse How the CS should react when an RCD signal (6mA DC leakage detected) arrives from the RCD unit.
Options:
- Smart: Stop charging by allowing the EV to stop its charging process itself. When the EV does not respond within 5 seconds, shut off the power.
- Immediate: Immediately shut off any charging process when a digital signal from RCD unit arrives.
Default: Smart
For instance: Smart,Immediate

Type: String
Read / Write No Alfen
Monitoring AlfenConnector Connector1-ActualPower ActualPower Displays the actual power (kW) that is being consumed at connector #1. Default: ''
Type: Decimal
Read only No Alfen
Monitoring AlfenConnector Connector1-InputPhases InputPhases Displays the number of mains voltage phases that are measured on the input side of connector #1. Default: ''
Type: Integer (0 - 3)
Read only No Alfen
Monitoring AlfenConnector Connector1-OutputPhases OutputPhases Displays the number of mains voltage phases that are measured on the output side of connector #1. Default: ''
Type: Integer (0 - 3)
Read only No Alfen
Monitoring AlfenConnector Connector1-PhasesConnected PhasesConnected The mains power phases that are connected to the input side of connector #1. Default: Determined per order
Type: String
Read only No Alfen
Monitoring AlfenConnector Connector2-ActualPower ActualPower Displays the actual power (kW) that is being consumed at connector #2. Default: ''
Type: Decimal
Read only No Alfen
Monitoring AlfenConnector Connector2-InputPhases InputPhases Displays the number of mains voltage phases that are measured on the input side of connector #2. Default: ''
Type: Integer (0 - 3)
Read only No Alfen
Monitoring AlfenConnector Connector2-OutputPhases OutputPhases Displays the number of mains voltage phases that are measured on the output side of connector #2. Default: ''
Type: Integer (0 - 3)
Read only No Alfen
Monitoring AlfenConnector Connector2-PhasesConnected PhasesConnected The mains power phases that are connected to the input side of connector #2. Default: Determined per order
Type: String
Read only No Alfen
Monitoring AlfenStation Temperature Measured temperature (°C) inside CS. Default: ''
Type: Decimal
Read only No Alfen
Monitoring AlfenStation StrictPEMeasurementEnabled protective earth detected enabled. Default: False
Type: Boolean
Read / Write No Alfen
Eichrecht AlignedDataCtrlr SignedDataEnabled SignReadings When set to true and an IVU adapter is present, the signed meter values will be sent to the BO at the start and stop of an transaction. Default: False
Type: Boolean
Read only No OCPP
Eichrecht SampledDataCtrlr SignReadings When set to true and an IVU adapter is present, the signed meter values will be sent to the BO at the start and stop of an transaction. Default: False
Type: Boolean
Read only No OCPP
Eichrecht AlfenStation SignedMeterValueUpdates This configuration key only works if the 'SignedDataEnabled' is set to true. By setting this flag to true the metervalue messages that are sent to the BO will contain a part with signed Eichrecht meter values. Default: False
Type: Boolean
Read / Write No Alfen
Eichrecht AlfenStation SignedStartStopMeterValue Include the signed data in an extra metervalue message to the BO at the start en stop transaction. Default: False
Type: Boolean
Read only No Alfen
Eichrecht AlfenEvse PublicKey-EnergyMeter1 PublicKey-EnergyMeter Public key of the first energy meter (if the energy meter contains a public key). Default: Determined per order
Type: String[40]
Read only No Alfen
Eichrecht AlfenEvse PublicKey-EnergyMeter2 PublicKey-EnergyMeter Public key of the second energy meter (if the energy meter contains a public key). Default: Determined per order
Type: String[40]
Read only No Alfen
Eichrecht AlfenStation PaymentCardIdTagPrefix Prefix for the payment card ID tag. Which if added and not used will not use Add-hoc tarrifs for Eichrecht chargers only. Default: ''
Type: String[4]
Read / Write No OCPP
Security None CertificateSignedMaxChain Maximum length of a certificate chain that can be installed. Default: 2
Type: Integer
Read only No OCPP
Security None CertificateStoreMaxLength Maximum number of Root/CA certificates that can be installed in the Charge Point. Default: 4
Type: Integer
Read only No OCPP
Security SecurityCtrlr CertificateSignedMaxChainSize MaxCertificateChainSize Maximum length of a certificate chain that can be installed via a CertificateSigned request. Default: 7000
Type: Integer
Read only No OCPP
Security SecurityCtrlr CpoName OrganizationName This configuration key contains CPO name (or an organization trusted by the CPO) as used in the Charge Point Certificate. Default: ''
Type: String[50]
Read / Write No OCPP
Security AlfenStation PW-SetChargerPassword Change the charging station's password
Existing and new password, comma seperated: {existing},{new}
Minimum length: 10 alphanumeric characters
Max. length: 40 characters
Excluded are backslash, double quote and commas.
Default: ''
Type: String
Read / Write No Alfen
Security AlfenStation PW-ResetChargerPassword Reset the charging station's password. Default: False
Type: Boolean
Read / Write No Alfen
Security AlfenStation PW-SetTempAccessKey Allow temporary access with this password
Minimum length: 10 alphanumeric characters
Max. length: 40 characters
Excluded are backslash, double quote and commas.
Default: ''
Type: String
Read / Write No Alfen
Security AlfenStation PW-TempAccessExpiration Number of hours left, rounded up. Default: ''
Type: String
Read / Write No Alfen
Security AlfenStation PW-EndUserAccessKey The password of the end user
The password either is unset (equal to admin password), empty or a 4 to 6 digit pin.
When retrieving the configuration parameter, this returns 'PIN' when a pin is set, '*****' when unset and '' when empty.
Default: ''
Type: String
Read / Write No Alfen
Security AlfenStation PW-AllowSSALogin Allow Secure Service Access. Default: False
Type: Boolean
Read / Write No Alfen
Security AlfenStation SecurityProfile This configuration key is used to set the security profile used by the charging station. The value of this configuration key can only be increased to a higher level, not decreased to a lower level. After the security profile was successfully changed, the charging station disconnects from the backoffice and will reconnect using the new configured Security Profile. Default: 0
Type: Integer (0 - 3)
Read / Write No Alfen
Price transparency AlfenStation Pricing-Currency The ISO 4217 currency code for the pricing information that can be shown on the display. Note that some ISO codes will be automatically converted to a currency symbol. Default: EUR
Type: String[3]
Read / Write No Alfen
Price transparency AlfenStation Pricing-StartPrice The start price for a charging session (for display purposes only). Default: 0.0
Type: Decimal (-999.995 - 999.995)
Read / Write No Alfen
Price transparency AlfenStation Pricing-EnergyPrice The price per kWh for a charging session (for display purposes only). A pricing information block will only be shown on the 'Available' screen. Default: 0.0
Type: Decimal (-999.995 - 999.995)
Read / Write No Alfen
Price transparency AlfenStation Pricing-MinutePrice The price per minute for a charging session (for display purposes only). A pricing information block will only be shown on the 'Available' screen. Default: 0.0
Type: Decimal (-999.995 - 999.995)
Read / Write No Alfen
Price transparency AlfenStation Pricing-Other The price per custom specifier (for display purposes only). A pricing information block will only be shown on the 'Available' screen. Default: 0.0
Type: Decimal (-999.995 - 999.995)
Read / Write No Alfen
Price transparency AlfenStation Pricing-OtherSpecifier The pricing specifier of the other tariff. Default: ''
Type: String[32]
Read / Write No Alfen
Price transparency AlfenStation Pricing-ShowComponent Determine if the disclaimer should be shown and which tariffs. Comma separated list, options:
- disclaimer-NonAfir
- disclaimer-Afir
- perKwh
- perMinute
- perSession
- perOther
Disclaimer options are mutually exclusive.
Default: ''
For instance: disclaimer-NonAfir,disclaimer-Afir,perKwh,perMinute,perSession,perOther

Type: Memberlist
Read / Write No Alfen
Direct Payment Solutions AlfenEvse QRCodeURL QR to be shown on the left socket. Default: ''
Type: String[193]
Read / Write No Alfen
Direct Payment Solutions AlfenEvse QRCodeURL2 QRCodeURL QR to be shown on the right socket. Default: ''
Type: String[193]
Read / Write No Alfen
Direct Payment Solutions AlfenStation DPSAvailableMethods A comma-separated list of the Direct Payment Solutions that are available. If no Direct Payment Solutions are available, this configuration key is hidden. Options:
- Giro-e
- QR
- OTS
Default: Determined per order
For instance: OTS,QR,Giro-e

Type: Memberlist
Read only No Alfen
Direct Payment Solutions AlfenStation DPSConfiguredMethods A comma-separated list of the Direct Payment Solutions that are configured. If no Direct Payment Solutions are available, this configuration key is hidden. Options:
- Giro-e
- QR
- OTS
Default: ''
For instance: OTS,QR,Giro-e

Type: Memberlist
Read / Write No Alfen
Other None GetConfigurationMaxKeys The maximum number of keys in a GetConfiguration message. Default: 35
Type: Integer
Read only No OCPP
Other None NumberOfConnectors Number of connectors.
- Eve Single: 1
- Eve Double: 2
- Twin: 2
Default: Determined per order
Type: String
Read only No OCPP
Other ReservationCtrlr ReserveConnectorZeroSupported NonEvseSpecific If this configuration key is set to true the CS supports reservations for connector 0 (complete CS). Default: True
Type: Boolean
Read only No OCPP
Other OCPPCommCtrlr ResetRetries Number of times to retry an unsuccessful reset of the CS. This key is read/write in order to satisfy the OCPP specification, but can only be set to 0. Default: 0
Type: Integer
Read / Write No OCPP
Other AlfenStation ForceFirmwareRollback Manually force a firmware rollback by setting this configuration key to the current firmware version build number. NOTE: Only use this if absolutely necessary, firmware rollbacks can cause database issues and undefined behavior regarding Transactions. Default: ''
Type: String
Write only No Alfen